CBVWB - SMOKEMASTER FLUID, 1C1-001-786
- MSDS: CBVWB
- Manufacturer: SYMPTRON SYSTEMS INC
- Product Name: SMOKEMASTER FLUID, 1C1-001-786
- National Stock Number: 6850-00N043229
Product Identification
Product ID:SMOKEMASTER FLUID, 1C1-001-786
MSDS Date:04/12/1993
FSC:6850
NIIN:00N043229
MSDS Number: CBVWB
Responsible Party
FAIR LAWN, NJ 07410
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 201-794-0200
Cage: 0HJF2
Contractor
Telephone: 201-794-0200
Cage: 0HJF2
Ingredients
OPEN FLAME AS WOULD BE PRESENT IN FIRE TRAINING
RTECS: 9999999ZZ
PRESENT IN THIS PROD. WHILE THESE TRACE QTYS ACCUM IN
RTECS: 9999999ZZ
NOT EXPECTED TO CREATE CNDTN WHICH WILL RSLT IN EO
RTECS: 9999999ZZ
APPROPRIATE APPLICATIONS, OSHA HAS ESTABLISHED PEL OF
RTECS: 9999999ZZ
ETHYLENE GLYCOL (SARA 313) (CERCLA)
CAS: 107-21-1
RTECS: KW2975000
Fraction By Weight: <10%
OSHA PEL N/K
ACGIH TLV: 50 PPM, VAPOR, C
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
<0.5 PPM.
CAS: 75-21-8
RTECS: KX2450000
Fraction By Weight: <0.1%
OSHA PEL 1 PPM
ACGIH TLV: 1 PPM
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:MAY CAUSE SLIGHT TRANSIENT
(TEMPORARY) IRRIT. SKIN CONT:PRLNG EXPOS IS NOT LIKELY TO CAUSE
SIGNIFICANT IRRIT. RPTD EXPOS MAY CAUSE SLIGHT FLAKING, TENDERNESS
& SOFTENING OF SKIN. MAY CAUSE MORE S EV RESPONSE IF SKIN IS
ABRADED (SCRATCHED/CUT). SKIN ABSORPTION:FLUID MAY CAUSE SLIGHT
IRRIT AFTER (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:PRLNG CONT. (SINGLE PRLNG EXPOS IS NOT
LIKELY TO RSLT IN MATL BEING ABSORBED IN HARMFUL AMTS).
INGEST:SINGLE DOSE ORAL TOX IS LOW. NO HAZS ANTIC FROM INGEST
INCIDENTAL TO INDUS EXPOS. INHAL:S INGLE PRLNG (HRS) EXPOS IS NOT
LIKELY TO CAUSE ADVERSE EFTS. MISTS ARE NOT LIKELY TO BE HAZ. VAPS
AT ROOM TEMP (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . EYES:IRRIGATE IMMEDIATELY
W/WATER FOR AT LEAST 15 MINUTES. IF IRRITATION PERSISTS, CONTACT
MD. SKIN:WASH OFF IN FLOWING WATER OR SHOWER. NOTE TO MD:NO
SPECIFIC ANTIDOTE. SUPPORTIVE CARE. TREATMENT BASED ON JUDGMENT OF
MD IN RESPONSE TO REACTIONS OF PATIENT.
Fire Fighting
Flash Point:244F,118C
Extinguishing Media:WATER FOG, ALCOHOL FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:COMBUSTIBLE IF HEATED.
Accidental Release
Spill Release Procedures:SMALL SPILLS:COVER W/ABSORBENT MATERIAL, SOAK
UP & SWEEP INTO A DRUM. LARGE SPILLS:DIKE AROUND SPILL & PUMP INTO
SUITABLE CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:EXERCISE REAS CARE & CAUT. THIS PROD
MAY DECOMP @ ELEVATED TEMPS, GENERATING VAPS WHICH COULD BE IRRIT.
FOR USES AT ELEVATED TEMPS, VENT/EXHST IS REC.
Other Precautions:EXTENDED EXPOS TO SYNTHETIC SMOKE PARTICULATE/VAP
PRODS FROM THIS FLUID CAN CAUSE DISCOMFORT TO PERS WHO ARE EXPER
SYMPS OF RESP/EYE IRRIT. IT IS REC THAT THOSE PERS WEAR APPROP PROT
EQUIP. THIS CAUT DOES NOT APPLY TO PERS EXPOS TO (SUPDAT)
Exposure Controls
Respiratory Protection:WHEN AIRBORNE EXPOSURE GUIDELINES &/OR COMFORT
LEVELS MAY BE EXCEEDED, USE A NIOSH APPROVED AIR-PURIFYING
RESPIRATOR. NIOSH APPROVED ORGANIC VAPOR RESPIRATORS W/PARTICULATE
FILTERS CAN BE USED TO DECR EASE EXPOSURE.
Ventilation:GOOD GENERAL VENTILATION SHOULD BE SUFFICIENT FOR MOST
CONDITIONS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP:ARE UNLIKELY DUE TO PHYSICAL PROPERTIES. OTHER
PREC:THIS MATL ON INFREQUENT BASIS. USE OF THIS SMOKE AGENT IS NOT
REC IN SM, NON-VENTED COMPARTMENTS. ADEQ VENT SHOULD BE AVAIL &
EXCESS IVE SMOKE/VAP DENSITIES SHOULD BE AVOIDED. SYNTHETIC SMOKE
PARTICULATE/VAP PRODS FROM FLUID SHALL NOT BE EXPOS TO(ING 3)
Chemical Properties
Boiling Pt:B.P. Text:379F,193C
Vapor Pres:14.33 @20C
Spec Gravity:1.0446
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS/VISCOUS LIQUID; LOW ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS.
Stability Condition to Avoid:PROD DEGRADES WHEN STORED AT ELEVATED
TEMPS IN PRESENCE OF AIR. DEGRADATION OCCURS RAPIDLY AT TEMPS
APPROACHING FL PT.
Hazardous Decomposition Products:PROPLONALDEHYDE, CARBON MONOXIDE IN
THE PRESENCE OF LIMITED OXYGEN IN A FIRE SITUATION.
Disposal
Waste Disposal Methods:REPROCESS OR BURN IN AN APPROVED CHEMICAL
INCINERATOR I/A/W ALL FEDERAL, STATE & LOCAL REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their